How the Pressure Equipment Directive classifies
The Pressure Equipment Directive 2014/68/EU (PED, in German DGRL) applies to pressure equipment with a maximum allowable pressure PS above 0.5 bar. It divides vessels, piping and pressure equipment subject to flame or heating into categories according to their hazard. The higher the category, the stricter the conformity assessment procedure. The classification always follows the same four steps.
1. Fluid group
Under Article 13, group 1 covers dangerous substances under the CLP Regulation: unstable explosives, flammable gases, oxidising gases, flammable liquids of categories 1 and 2 and of category 3 if the maximum allowable temperature is above the flash point, acutely toxic substances and some other classes. Everything else is group 2 – including water, steam, compressed air, nitrogen and carbon dioxide.
2. Physical state
Treated as a gas are gases, liquefied gases, gases dissolved under pressure, vapours and all liquids whose vapour pressure at TS is more than 0.5 bar above normal atmospheric pressure, i.e. above 1.513 bar absolute. For water this limit is 111.5 °C: hot water with TS 130 °C is a group 2 gas within the meaning of the Directive.
3. Table and category
Component, fluid group and state lead to one of the nine tables in Annex II:
| Component | Gas gr. 1 | Gas gr. 2 | Liquid gr. 1 | Liquid gr. 2 |
| Vessel (PS, V) | 1 | 2 | 3 | 4 |
| Piping (PS, DN) | 6 | 7 | 8 | 9 |
| Subject to flame or heating, steam/hot water above 110 °C, V above 2 L | 5 |
In the table, the point from PS and DN or PS and V lies in one field: Article 4(3) or category I to IV. Two exceptions are built in: piping and vessels for unstable gases move from category I or II to category III, and piping under table 7 above 350 °C moves from category II to category III.
Article 4(3) means: the equipment must be designed and manufactured in accordance with sound engineering practice, but receives no CE marking and no conformity assessment procedure.
4. Modules and certificates
For each category, Annex II permits certain conformity assessment modules under Annex III. The manufacturer chooses one of them; modules of a higher category are also allowed.
| Category | Modules | Certificate (practice) |
| Art. 4(3) | – | 2.1 |
| I | A | 2.2 |
| II | A2, D1, E1 | 3.1 / 3.2 |
| III | B (design type) + D, B (design type) + F, B (production type) + E, B (production type) + C2, H | 3.1 / 3.2 |
| IV | B (production type) + D, B (production type) + F, G, H1 | 3.1 / 3.2 |
The certificates refer to the materials of the main pressure-bearing parts to EN 10204. From category II, Annex I section 4.3 requires specific product control, i.e. at least an inspection certificate 3.1.
Frequently asked questions
How do I determine the PED category of a pipe?
With four inputs: fluid group, physical state at TS, maximum allowable pressure PS and nominal size DN. This gives table 6 to 9 of Annex II and, within it, the category. That is exactly what this calculator does.
Fluid group 1 or 2 – what applies to water and steam?
Water and steam are group 2. Group 1 covers dangerous substances such as natural gas, hydrogen, oxygen or ammonia; oils belong to it if TS is above the flash point.
Does water above 110 °C count as a gas?
Above 111.5 °C, yes. Its vapour pressure is then above 1.513 bar absolute, and piping is classified using table 7 instead of table 9. The calculator checks this automatically using the IAPWS-IF97 saturation curve.
Does piping need CE marking?
From category I onwards, yes, with an EU declaration of conformity. Below that, Art. 4(3) applies: sound engineering practice, no CE marking.
What does Article 4(3) mean?
Sound engineering practice: safely designed and manufactured, with instructions for use and manufacturer identification, but without conformity assessment and without CE marking.
Is PS the operating pressure?
No. PS is the maximum pressure specified by the manufacturer for which the equipment is designed – usually the set pressure of the safety valve, not the normal operating pressure. Likewise, TS is the maximum allowable temperature, not the operating temperature.
Which modules are there per category?
I: A · II: A2, D1, E1 · III: B + D, B + F, B + E, B + C2, H · IV: B + D, B + F, G, H1. The calculator shows the permitted modules with the result.
Which module should I choose?
That is the manufacturer’s decision. For category II piping, A2 is common; for category III often B + F or H, depending on whether a certified quality assurance system exists.
When do I need a notified body?
From category II. In category I (module A), the manufacturer declares conformity alone.
Which material certificate do I need, 2.2 or 3.1?
Common practice: Art. 4(3) test report 2.1 (declaration of compliance), category I 2.2, from category II inspection certificate 3.1 or 3.2 to EN 10204 for the main pressure-bearing parts.
Is a plant an assembly under the PED?
Only if a manufacturer combines several pieces of pressure equipment into one unit and places it on the market as such. A plant assembled on site under the responsibility of the operator is usually not an assembly.
Why DN and not the inside diameter?
For piping, the Directive uses the nominal size DN as a dimensionless figure. The product PS · DN is therefore given in bar.
What does the calculator cost?
Nothing. The PED calculator is free to use without sign-up. More free calculators, for example for the PN rating to EN 1092-1, are under Free calculators. Found a bug or have a wish? Post it on the feedback page.
Detailed explanation with examples (in German): Druckgeräterichtlinie 2014/68/EU – classification, modules and CE marking on ce-im-anlagenbau.de.