Free · EN 1092-1 · with a free account

PN calculator

Which pressure rating does the flange need? Enter material, pressure PS and temperature TS: the calculator determines the required PN to EN 1092-1, the allowable pressure at TS and the utilisation.

Inputs

No warranty: result based on the pressure/temperature ratings of EN 1092-1 for flanges (material group, smallest wall thickness/strength range, linear interpolation between temperatures). Applies to flanges and flange-determined components; pipes, valves and gaskets have their own limits. The standard tables are kept on the server only and are not output. Checking and using the results is the responsibility of the user.

Next step

PN for all the lines of a plant?

In the heat balance tool, the line list, piping classes with PS, TS and PN and the PED classification of every line follow directly from the heat and pressure balance.

Open the heat balance tool

What the PN calculator does

The pressure rating PN (pression nominale) is a reference figure for flanges and piping components: PN 16 means the part withstands 16 bar gauge at room temperature. As the temperature rises, the strength of the material and thus the allowable pressure decrease. A PN 16 flange made of P265GH carries considerably less than 16 bar at 300 °C.

This is why it is not enough to simply choose a PN larger than the pressure. The calculator looks for the smallest standard rating whose allowable pressure at your temperature TS reaches at least your pressure PS, and shows you the material group and the utilisation.

Method

  1. Assign the material to a material group under EN 1092-1 (e.g. 3E0 for unalloyed steels with elevated-temperature properties).
  2. For each rating from PN 2.5 upwards, read the allowable pressure of the group at TS, interpolated linearly between the table temperatures.
  3. Take the smallest rating whose allowable pressure is at least PS. If TS lies in the creep range, the calculator points this out.

Typical pressure ratings

PN 2.5 · 6 · 10 · 16 · 25 · 40 · 63 · 100 · 160 · 250 · 320 · 400. In practice, PN 10 or PN 16 is often the minimum used, even if the calculation allows less.

Why sign up?

The rating tables of the standard are protected by copyright. They stay on the server; the calculator only outputs the result of your query. With a free Toolmeyer account you have 40 queries per day. For whole plants, the heat balance tool derives PS, TS and PN of every line automatically (piping classes, Professional).

Frequently asked questions

What does PN 16 mean?

Nominal pressure 16: the component is designed for 16 bar gauge at room temperature. At higher temperatures the allowable pressure is lower; how much lower depends on the material group.

Is the nominal pressure the operating pressure?

No. PN is a step in a series of components. What matters is that the allowable pressure of the chosen rating at the design temperature TS reaches at least the maximum allowable pressure PS of the plant.

Does the result also apply to valves?

For valves, the manufacturer’s data and the relevant product standard apply. The calculator refers to flanges to EN 1092-1.

Why do I need an account?

So that the copyrighted standard tables are not queried in bulk. The account is free; signing up takes a minute.

What does the calculator cost?

Nothing. Free with a Toolmeyer account, 40 queries per day.

← All free calculators

Transparency

How we calculate

  • Rating to EN 1092-1 with material group and temperature derating
  • Source in the result: standard and table the value comes from
  • Standard tables stay protected on the server – you get the result of your query
  • PS/TS rules openly available, based on EN 13480-3 and EN 12952-3
See the calculation basis