What are steam tables?
Steam tables list the thermodynamic properties of water and steam: pressure p, temperature T, specific volume v, density ρ, enthalpy h, internal energy u and entropy s. Anyone calculating a boiler, a turbine, a heat exchanger or a thermodynamic cycle needs these values in almost every step – in a thermodynamics exercise just as in power plant design.
In the past, the values were looked up in printed tables and interpolated between the rows. This calculator gives them directly for any state, without interpolation errors, and shows the point in the h-s and T-s diagram at the same time.
How to use the calculator
A state of pure water is fixed by two independent quantities. Choose the pair you know:
- p and T – the normal case for subcooled liquid and superheated steam.
- p and x or T and x – for wet steam and saturation (x = 0 saturated liquid, x = 1 saturated steam). In the wet steam region p and T are tied together; there p and T alone are not enough.
- p and h – after throttling (h stays the same) or mixing.
- p and s – for isentropic compression or expansion (pump, turbine).
- h and s – to read a point from the Mollier chart.
With Two states you calculate the start and end of a change of state and get Δh, Δs and – for an expansion – the isentropic efficiency. Copy link lets you share any state.
Reading the h-s diagram (Mollier chart)
The h-s diagram plots enthalpy against entropy. The thick line is the saturation curve: to its left the saturated liquid (x = 0), to its right the saturated steam (x = 1), below it the wet steam region, at the top the critical point at 374 °C and 220.6 bar. Isobars (blue) run as straight lines in the wet steam region and rise steeply in the steam region; isotherms (red) bend at the saturation curve and become almost horizontal in the superheated region – there steam behaves more and more like an ideal gas.
The big advantage: a turbine expansion is an almost vertical line in the h-s diagram, and the enthalpy difference – the work per kilogram of steam – can be read directly as a height.
Reading the T-s diagram
In the T-s diagram the area under a change of state equals the heat supplied or removed (for reversible processes). This is why it shows cycles such as the Rankine cycle particularly clearly: evaporation in the boiler is a horizontal line in the wet steam region, isentropic expansion a vertical one. The higher the mean temperature of heat addition, the better the efficiency – which is exactly what superheating, reheating and feedwater preheating achieve.
Steam quality, wet steam and saturation
In the wet steam region, saturated liquid and saturated steam exist side by side. The steam quality x is the mass fraction of the vapour. The properties follow as a mixture, for example h = h′ + x · (h″ − h′). The difference r = h″ − h′ is the enthalpy of vaporisation; it decreases towards the critical point and vanishes there completely.
Worked example: expansion in a steam turbine
Live steam at 100 bar and 500 °C is expanded to 0.1 bar in a condensing turbine. The isentropic turbine efficiency is 85 %.
Inlet (p, T): h₁ = 3375.1 kJ/kg s₁ = 6.5993 kJ/(kg·K)
Isentropic to 0.1 bar: h₂ₛ = 2089.6 kJ/kg x₂ₛ = 0.793
Actual (η = 0.85): h₂ = h₁ − 0.85 · (h₁ − h₂ₛ) = 2282.5 kJ/kg x₂ = 0.874
Specific work: w = h₁ − h₂ = 1092.6 kJ/kg
Open this example in the calculator – state B with p and h shows the end point, and the isentropic efficiency is calculated as well.
Basis: IAPWS-IF97
The calculator uses the industrial formulation IAPWS-IF97 of the International Association for the Properties of Water and Steam, regions 1 to 4: liquid, steam, the region around the critical point and the saturation line. Valid from 0 °C to 800 °C and up to 1000 bar. The values are tested against the verification values of the formulation. High-temperature steam above 800 °C (region 5) is not included.
Frequently asked questions
Are the pressures absolute?
Yes. All pressures are absolute. A gauge pressure of 5 bar corresponds to about 6.01 bar absolute.
Why is there no cp for wet steam?
In the wet steam region, adding heat only changes the steam quality, not the temperature. The specific isobaric heat capacity is infinite there and is therefore not given.
Where is the zero point of enthalpy and entropy?
As in all common steam tables: u = 0 and s = 0 for saturated liquid at the triple point (0.01 °C, 611.657 Pa).
Can I copy the saturation table into Excel?
Yes. “Copy table” puts the values tab-separated on the clipboard; just paste them into Excel.
What does the calculator cost?