How the power-to-heat calculator works
Power-to-heat means: in hours with low power prices, often with plenty of wind and sun, an electrode boiler or heat pump turns electricity into heat for the district heating network and displaces heat from the gas boiler. Without a store, the plant can only deliver as much heat as the network needs in exactly those hours. On windy summer nights in particular, that is not much.
1. What is the thermal store for?
The store takes the heat that the network cannot take during the price dip and releases it afterwards. Its capacity follows from volume, temperature difference and usable share: Q = V · ρ · cp · (Ttop − Tbottom). 5,000 m³ at 95/60 °C hold around 190 MWh.
2. Method
The cheap hours come in price dips of the given duration. In each price dip the plant delivers at most its full heat output, but no more than network demand plus free storage capacity. The calculator assumes that the store is discharged again before the next price dip. The heat gained replaces gas boiler heat; the saving is the difference in heat cost minus storage losses and capital cost.
3. What the calculator does not cover
Real price time series, revenues on the balancing market, special grid fee rules, the role of a CHP plant in the same network and the hydraulics of the integration. For network operation with storage there are two ready-made heat balance diagrams: District heating network with thermal store and Flexible CHP with thermal store.
Frequently asked questions
What is power-to-heat?
Converting electricity into heat, in district heating mostly with electrode boilers or large heat pumps. It pays off above all in hours with low power prices and then replaces heat from gas or coal.
Electrode boiler or heat pump?
An electrode boiler is cheap to buy, quick to control and reaches almost 100 % efficiency, but turns 1 MWh of power into only 1 MWh of heat. A heat pump turns it into two to four times as much, but costs many times more and is economical rather with many operating hours per year.
How large must the thermal store be?
Large enough to take the heat from a typical price dip that the network does not take directly: roughly (heat output − network demand) · duration of the price dip. The chart shows from which size more volume no longer helps.
How much heat fits into a thermal store?
About 11 MWh per 1,000 m³ of water and 10 K temperature difference. At 95/60 °C that is about 39 MWh per 1,000 m³, minus the mixing zone.
What does the calculator cost?
Nothing. It is free to use without sign-up.